ARN Series Certified Adaptors and Reducers provide a method of matching electrical threadforms on Ex equipment while maintaining Increased Safety Exe methods of explosion protection and IP66, 68 for IEC type applications.

Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the entry thread of the enclosure.

Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread.
 
CERTIFICATION CENELEC
SIRA00ATEX3091 (Metric Female)
SIRA99ATEX3116U (Non-Metric Female)
II 2DG E Ex e II

CSA / A Ex
Class I, Zone 1, Ex e II
Class I, Division 2 ABCD
Class II EFG, Class III
INGRESS
PROTECTION
IP66 68, CSA Enclosure Type (NEMA) 4X 6P
IMPACT RESISTANCE 7Nm
OPERATING TEMPERATURES Nitrile O Ring -30C to +100C
Silicone O Ring -50C to +125C
MATERIALS
30% Glass Filled Nylon (ARN)
THREADS ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
SEALS The standard O Ring material is Nitrile
EXAMPLE PART NUMBER Sample: ARN/M20/M25
ARN - Body material (Nylon)
M20 - Male thread size
M25 - Female thread size
GAVAILABLE THREAD SIZES AND CORRESPONDING BORE SIZE
Metric Bore NPT Bore ISO Pipe Bore ET Bore PG Bore
M16 9.3 9 9.0
M20 11.0 1/2" 12.0 1/2" 12.0 3.4" 11.0 11 10.0
M25 16.0 3/4" 13.0 3/4" 13.0 1 16.0 13.5 11.5
M32 21.0 1 18.0 1 18.0 1*1/4" 21.0 16 13.5
M40 31.0 1*1/4" 33.0 1*1/4" 33.0 1*1/2" 31.0 21 19.0
M50 40.0 1*1/2" 38.0 1*1/2" 38.0 2 40.0 29 28.0
36 37.0
42 44.0
All Dimensions are in Millimetres
NOTES:
  • Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and adhered to in full
  • Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
  • Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the entry thread of the enclosure
  • Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread

 

Peppers America, Inc
875 Via De La Paz, Suite D
Pacific Palisades, CA 90272
310-459-1605
Part of the North American Sales Company